2720 Southgate Way

Sold Industrial Property (SC001069)

Address:
2720 Southgate Way
Plant #2-Master Vac
Sumter County
Sumter, SC 29150
Location:
Approximately 46 miles east of Columbia
Building Size:
95,577 SF
Lot Size:
18 Acres + 10.61 Acres
18 acres available. Additional 10.61 acre parcel available for purchase.
Property Description
Year Built
1986 / 1992
1986: 68,000 square feet
1989: 23,500 square feet
1992: 4,277 square feet
Quality
Excellent
Office
9,175 SF
9,175 square feet of good general purpose manufacturing office space and cafeteria featuring carpet and tile floors, sheetrock and acoustical tile with modern fluorescent lighting. 3,035 square feet of mezzanine plant support offices and quality control lab space not counted in overall square footage.
Dimensions
241' x 331'
Ceiling Height
Min: 24' 2", Max: 24' 2"
Column Spacing
40' x 40'
Column Comments
8"
Column Type
Steel H
Roof
Built-up - Built up roof (orginal roof with annual maintenance)
Floors
6" Reinforced Concrete
Walls
Metal -- insulated
Lighting
400 watt high pressure sodium vapor
Loading
North Wall
1-10’ x 14’ rapid roll up drive-in door.

Covered platform with 8 positions accessed by 1 – 10’ x 12’ rapid roll door. 5 positions with load levelers and 3 without.

1 drive up ramp to access truck court.

South Wall
1-10’ x 14’ rapid rollup drive-in door.
1-10’ x 16’ rapid rollup drive-in door.

Covered platform with 8 positions accessed by
2 – 10’ x 10’ rapid roll door. 5 positions with load levelers and 3 without.

1 drive up ramp to access truck court.
Cranes
1-5 ton with 2 – 2.5 ton electric pulleys with 16’ clear under hook, 45’ span and 60’ travel.
Parking
344 paved, marked and lighted spaces
Rail
No
Gas
SC Electric & Gas - 6" main, 2" line
Water
City
Sewer
City
Power
Progress Energy
Primary: 23 kv, 3 phase line

Secondary: 3 – 3,000 amp Square D switchgear.
Transformers: 1-2,500 kva pad mounted transformer

Distribution: 3-800 amp bus duct
Heat
Gas
Combination gas fired unit heaters for heating
Air Conditioning
Yes - Combination gas fired unit heaters for heating and cooling
Sprinklers
Yes - 100% wet/dry system for covered loading areas
Air Line
2 – 400 hp Ingersoll Rand air compressors, one at 1476 cfm installed in 1990 and one at 1500 cfm installed in 1982.

2 – Ingersoll Rand air dryers

1 – Accumulation tank

2 – Vacuum pumps

Air lines throughout the facility
Special Features
240 ton 4 stage chiller for process cooling installed in 1999.

Fire pump house which houses back up diesel fire pump.
Miscellaneous
Fencing along the sides and rear of the facility. There is a guard gate for truck access. Employees access the facility via ID cards.
Last Use
Assembly of master cylinders for brakes for passenger cars and light trucks.
Hart Corporation - New Hart Corporation - 7422 Carmel Executive Park, Ste. 216 - Charlotte, NC 28226 - 704.541.1393 - hart@hartcorp.com
All information furnished is from sources deemed reliable, but no warranty or representation is made as to the accuracy thereof and same is submitted subject to errors, omissions, change of price, rental or other conditions, prior sale, lease or financing, or withdrawal without notice. No liability of any kind is to be imposed on the broker herein.
Bookmark and Share